1. Full cylinder tank life
Nominal capacity 125 ft³; remaining 100%; flow 25 CFH; gas-on 100%.
- Available gas: 125 ft³ × 100% = 125 ft³.
- Continuous runtime: 125 ft³ / 25 ft³/hr = 5 hr.
- Session runtime: 5 hr / 1 = 5 hr.
Estimate shielding-gas runtime and job consumption from your entered volume and flow.
Enter nominal usable gas volume at the stated standard/reference basis supplied or labeled by you or your supplier. Capacity and flow must use a compatible reference basis. This is gas volume, not cylinder water volume; pressure, temperature and dimensions are not modeled.
Entered directly, from 0 to 100%. Available gas = nominal capacity × remaining percentage.
Enter a positive flow rate from your equipment or job plan. This calculator does not recommend a setting.
Estimated share of the work session during which shielding gas is actually flowing. Above 0 and at most 100%.
Leave blank to estimate runtime only; zero is allowed.
Requires nominal capacity. Planning allocation only; suppliers may charge fixed prices, rental, fees, tax or delivery.
Enter up to five flows in CFH. Higher entered flow increases gas consumption and reduces estimated runtime.
User-entered scenarios only; no optimum flow or high-flow threshold is assigned.
Remaining gas percentage is entered directly. Cylinder pressure is not converted to remaining gas because pressure/content relationships vary by gas, temperature, cylinder type, and whether the gas is compressed or liquefied.
For liquefied gases such as CO₂, pressure gauge readings do not provide a simple linear remaining-volume percentage.
Gas-on percentage is a planning estimate. Actual consumption may include pre-flow, post-flow, purging, setup losses, leaks, and other periods when gas flows without active welding.
Continuous flow at the entered shielding-gas rate.
Compressed-gas note: This calculator estimates gas usage from entered volume and flow. It does not determine cylinder pressure, regulator settings, gas compatibility, storage/handling requirements, ventilation, fire risk, or welding-process safety.
Use gas-flow settings appropriate to your welding process, torch/nozzle/cup, gas mixture, environment, and equipment/manufacturer guidance.
Actual consumption may be higher because of leaks, purging, pre-flow/post-flow, setup losses, and real working patterns.
This is a volume-budget visual only, not actual cylinder pressure, liquid level or physical fill height.
Arithmetic uses the same full-precision engine as the result. Display rounding is applied only afterward.
Welding Gas Consumption Estimator Tank Life Available gas: 125 ft³ Shielding-gas flow rate: 25 CFH Continuous runtime: 5 hr 0 min (5 decimal hr) Gas-on adjusted session runtime: 5 hr 0 min (5 decimal hr) Available gas: 125 ft³ × 100% = 125 ft³. Continuous runtime: 125 ft³ / 25 ft³/hr = 5 hr. Session runtime: 5 hr / 1 = 5 hr. Remaining gas percentage is entered directly. Cylinder pressure is not converted to remaining gas because pressure/content relationships vary by gas, temperature, cylinder type, and whether the gas is compressed or liquefied. For liquefied gases such as CO₂, pressure gauge readings do not provide a simple linear remaining-volume percentage. Gas-on percentage is a planning estimate. Actual consumption may include pre-flow, post-flow, purging, setup losses, leaks, and other periods when gas flows without active welding. Compressed-gas note: This calculator estimates gas usage from entered volume and flow. It does not determine cylinder pressure, regulator settings, gas compatibility, storage/handling requirements, ventilation, fire risk, or welding-process safety. Use gas-flow settings appropriate to your welding process, torch/nozzle/cup, gas mixture, environment, and equipment/manufacturer guidance. Actual consumption may be higher because of leaks, purging, pre-flow/post-flow, setup losses, and real working patterns.
Estimate shielding-gas runtime, job consumption, gas remaining, and planning cost from cylinder capacity, available gas, flow rate, and gas-on time.
Choose Tank Life to estimate how long your shielding-gas cylinder will last, or Gas Needed to estimate job consumption. Enter nominal capacity and remaining percentage, shielding-gas flow, and optional session duration. Gas Needed starts with a 2 hr job; cylinder capacity is optional in that mode. Set gas-on percentage for intermittent flow. Advanced inputs offer a full refill/exchange price and up to five user-entered comparison flows. Copy or print the current valid estimate.
Reset restores Tank Life, 125 ft³ nominal capacity, 100% remaining, 25 CFH, 100% gas-on, blank job and cost, USD and no comparisons. Results are planning estimates, and are calculated locally in page memory.
Shielding-gas flow rate describes gas volume per time. This tool supports CFH, L/min and m³/h. CFH is cubic feet per hour, the prominent US welding unit here.
Using the exact international foot, 1 ft = 0.3048 m, so 1 ft³ = 28.316846592 L. Therefore 1 CFH = 28.316846592 / 60 = 0.4719474432 L/min. 25 CFH ≈ 11.7987 L/min. See NIST’s volume conversion factors (opens in a new tab). Volumes normalize to liters and flows to L/min. Unit switching preserves physical quantity; it does not adjust reference conditions.
Use gas-flow settings appropriate to your welding process, torch/nozzle/cup, gas mixture, environment, and equipment/manufacturer guidance. Process, gas, joint and environment affect selection. There is no universal recommended flow or high-flow warning threshold here.
Continuous runtime (hr) = available gas volume / flow rate (volume/hr). Available gas volume = nominal cylinder capacity × remaining percentage / 100. A full 125 ft³ cylinder at 25 CFH gives 5 hr 0 min. Rounding happens only for display.
Gas-on hours = job duration (hr) × gas-on percentage / 100. Gas needed = flow rate (volume/hr) × gas-on hours. With no optional capacity, Gas Needed still estimates job gas and gas-on time. Enter capacity to also see cylinder fraction, availability and whether the gas budget covers the job.
Available gas ≥ required gas means ENOUGH ESTIMATED GAS FOR THIS JOB; otherwise the result is ESTIMATED GAS SHORTFALL. Shortfall = required − available. Remaining after job = available − required; negative values are retained in the engine, with remaining gas floored at zero for display and shortfall shown separately. Remaining percentage = raw remaining after job / nominal capacity × 100, with a zero floor for display.
Enter nominal usable gas volume at the stated standard/reference basis supplied or labeled by you or your supplier. Capacity and flow must use a compatible reference basis. This is gas volume, not cylinder water volume; pressure, temperature and dimensions are not modeled.
Custom capacity input only. No universal cylinder-size preset dataset or purchase quantity is assumed. Equivalent cylinder fraction = gas required / nominal capacity, shown as a percentage of nominal cylinder capacity, not a recommendation to buy fractional cylinders.
Remaining percentage is user entered from 0–100. Available gas = capacity × remaining percentage / 100. For 125 ft³ at 60%, the engine gives 75 ft³. It applies this percentage once. Zero remaining gives zero available gas and zero runtime.
V1 uses only nominal capacity plus remaining percentage as its source of availability. There is no competing direct-volume override.
Remaining gas percentage is entered directly. Cylinder pressure is not converted to remaining gas because pressure/content relationships vary by gas, temperature, cylinder type, and whether the gas is compressed or liquefied.
For liquefied gases such as CO₂, pressure gauge readings do not provide a simple linear remaining-volume percentage. Air Products’ liquefied compressed-gas guidance (opens in a new tab) explains that pressure can persist while liquid remains. No pressure-derived percentage, pressure units, gas-law capacity calculation or cylinder dimensions are offered.
Gas-on percentage is the estimated share of the work session during which shielding gas is actually flowing. It is intentionally separate from arc-on duty cycle, and the two may differ.
Gas-on percentage is a planning estimate. Actual consumption may include pre-flow, post-flow, purging, setup losses, leaks, and other periods when gas flows without active welding. Enter above 0 and at most 100%; a zero-duration job can represent zero consumption without division by zero.
Estimated session runtime = continuous runtime / gas-on fraction. The continuous-flow estimate is the hero in Tank Life. At 40% gas-on, a 5 hr continuous gas budget covers an estimated 12 hr 30 min work session. This assumes that the entered fraction represents all gas-flow periods.
Hours and minutes are displayed together, while decimal hours remain available in result details and calculation steps. Whole-minute formatting can round small nonzero runtimes to 0 min.
Enter up to five alternative flow values in Advanced. Each scenario uses the same capacity, remaining percentage, job duration and gas-on percentage through the same engine. Higher entered flow increases gas consumption and reduces estimated runtime. Comparisons do not prescribe an optimum or judge weld quality. There is no process selector or process-specific flow default.
Allocated cost per volume = full refill/exchange price / nominal cylinder capacity. Continuous cost/hour = flow per hour × allocated cost per volume. Estimated allocated gas cost = job gas needed × allocated cost per volume. Job gas already includes the gas-on fraction, so cost does not assume full-session continuous flow.
Cost is omitted without both nominal capacity and full refill/exchange price. Currency is a display choice without FX conversion. This planning allocation can differ from fixed exchange/refill bills, rental, fees, tax, delivery or different fill quantities. It is not an actual refill-cost quote.
If you are pricing self-employed work, build a separate freelance labor-rate budget from your own income, overhead and billable-time assumptions. Gas-on time is not automatically billable labor, and gas costs should be included only once in the chosen budget.
Actual consumption may be higher because of leaks, purging, pre-flow/post-flow, setup losses, and real working patterns. A constant input rate cannot capture every work pattern or loss. Miller explains the role of pre-flow and post-flow (opens in a new tab), which can use gas while no arc is active. Include these periods in your gas-on estimate where possible.
Nominal capacity 125 ft³; remaining 100%; flow 25 CFH; gas-on 100%.
Nominal capacity 125 ft³; remaining 60%; flow 25 CFH; gas-on 100%.
Nominal capacity 125 ft³; remaining 100%; flow 25 CFH; gas-on 100%. Session 2 hr.
ENOUGH ESTIMATED GAS FOR THIS JOB
Nominal capacity 125 ft³; remaining 100%; flow 25 CFH; gas-on 40%. Session 2 hr.
ENOUGH ESTIMATED GAS FOR THIS JOB
Nominal capacity 125 ft³; remaining 60%; flow 25 CFH; gas-on 100%. Session 2 hr.
ENOUGH ESTIMATED GAS FOR THIS JOB
Nominal capacity 125 ft³; remaining 100%; flow 25 CFH; gas-on 100%. Session 2 hr. Full refill price $50.00.
ENOUGH ESTIMATED GAS FOR THIS JOB
Compressed-gas note: This calculator estimates gas usage from entered volume and flow. It does not determine cylinder pressure, regulator settings, gas compatibility, storage/handling requirements, ventilation, fire risk, or welding-process safety.
Use gas-flow settings appropriate to your welding process, torch/nozzle/cup, gas mixture, environment, and equipment/manufacturer guidance.
This volume-budget model assumes the entered usable gas capacity and flow share compatible standard/reference conditions. It does not estimate thermodynamics, regulator sizing, welding procedure parameters, mixture selection, weld quality, storage requirements or process safety. The budget visual represents entered gas volume only, not pressure or liquid level.
Capacity and flow must be positive and finite; remaining is 0–100%; gas-on is above 0–100%; duration and refill price may be zero but not negative. Malformed, NaN, infinite and overflowing inputs or results clear all calculated results and disable copy/print. Dot/comma decimals use the shared NumericInput. No input is stored in browser local or session storage, URLs, accounts or analytics payloads; calculations do not use a network service.
Divide available gas volume by shielding-gas flow in volume per hour. Apply your entered remaining percentage to nominal capacity first. This estimates continuous flow; a work session can last longer when gas is not always flowing.
Multiply flow per hour by job/session hours and the gas-on fraction. Use compatible volume and flow reference conditions.
CFH means cubic feet per hour: the volume of shielding gas flowing per hour at the stated reference basis. It is a flow unit, not a cylinder-pressure reading.
Multiply CFH by 28.316846592 / 60, or 0.4719474432. For example, 25 CFH is approximately 11.7987 L/min.
Available gas equals nominal capacity × remaining percentage / 100. At the same flow, a cylinder with 60% remaining has 60% of its full continuous runtime. Zero remaining gives zero runtime.
This calculator does not convert pressure to remaining percentage. Gas type, temperature and cylinder behavior matter. For liquefied gases such as CO₂, gauge pressure is not a simple linear indication of remaining volume. Enter the percentage directly.
It is the estimated share of the work session during which shielding gas is actually flowing. It is a planning input, and may differ from arc-on duty cycle because gas also flows before and after the arc.
Leaks, purging, pre-flow, post-flow, setup losses, varying flow and real work patterns can increase consumption. The estimate assumes a constant entered flow while gas is on.
Divide full refill/exchange price by nominal cylinder capacity, then multiply by estimated job gas. This is allocated planning cost. Fixed refill prices, rental, fees, tax, delivery and differing fill quantities can change the amount you pay.
No. It estimates volume usage and runtime only. Select flow using the welding process, torch/nozzle/cup, gas mixture, environment and equipment/manufacturer guidance. It does not judge weld quality or process safety.
Sources checked October 6, 2026 for unit definitions, shielding-gas flow context, pre/post-flow, liquefied-gas behavior and compressed-gas handling context. They do not endorse this calculator. Manufacturer flow tables are not reproduced and no flow-setting recommendation is imported.